Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Topic

Description

comment

Author

SynView Version

Petalinux Version

FPGA Version

Device Sensor Version

SynView Explorer

Brightness Control - BCRM Mode / Exposure Auto

Color Management -BCRM Mode / White Balance Auto
→ If "Once" is chosen, "Once" stays active. "OFF" is not active.

IAM-85

AKr

SynView-1.03.010.1090


2.02



34658

iAMGigEServer

Events can´t be send via GigE serverServer

.

MW

SynView-1.03.010.1090

2.02



SynView Explorer

Image Format:

Pixel format:
YUV-frame is brighter than BGR8-frame

Issue IAM-76

DP

SynView-1.03.010.1090

2.02

SynView Explorer

First frame occures to "flash"

GD

SynView-1.03.010.1090

2.02

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView IP Config Tool

sv.ipconf.x64

Re-enable the GigEVisionServer GigE Vision Server autostart sometimes fails after power cycle.

GD

SynView-1.03.010.1090

2.02

...

Expand
titleRelease 10/2020 - 1.04

Release 10/2020 - 1.04

Topic

Description

comment

Author

SynView Version

Petalinux Version

FPGA Version

BCRM Version

SynView Explorer

Brightness Control - BCRM Mode / Exposure Auto

Color Management -BCRM Mode / White Balance Auto
→ If "Once" is chosen, "Once" stays active. "OFF" is not active.

Issue IAM-85

AKr

1.03.010.1060




SynView Explorer

Events can´t be send via GigE serverServer

.

MW

1.03.010.1061-8.10.2020




SynView Explorer

Timer/puls Puls generator can´t be enabled or disabled with Acquisition Start/Stop

.

MW

1.03.010.1061-8.10.2020




SynView Explorer

TriggerMode: Trigger Invert operates sensor in free-run mode

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

StrobeMode: Strobe assigned to wrong edge

.

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

StrobeMode:  Strobe source: static Static low remains high

.

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

TriggerMode:  Software trigger
→ Strobe not available

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

I/O
→ Line5 OUT:  On -> Low, OFF → High

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

I/O:
→ Line4 OUT: no No function

.

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

Image Format:

Pixel format:
Format Bayer GR 10 Packed cannot be displayed
Format Bayer GR 10 Packed cannot be displayed

Issue SYN-16

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

Image Format:

Pixel format:
BayerRG8-frame is brighter than BGR8-frame

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

Image Format:

Pixel format:
YUV-frame is brighter than BGR8-frame

Issue IAM-76

DP

SynView Explorer

First frame occures to "flash"

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

Soft image due to missing basic sensor configuration

(gamma, black level)

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

...

Topic

Description

Affects

Author

Power supply

Power over Ethernet is not supported even though the camera will be detected as a PoE device by a PoE injector!

If the camera serial number has an X in the 9th digit (e.g. 14A2GEBAX2042013)

BH

Input and Output Interface

OUT_GP1+ is out of order and can be used in current revison. Output stays GND. This means in

SynView Explorer I/O: → Line4 OUT: no No function (always one!)

If the camera serial number has an X in the 9th digit (e.g. 14A2GEBAX2042013)

BH

...