Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 21 Next »

Software

Release 01/2022 - 3.10 (2021.1)

Topic

Description

comment

SynView Version

Petalinux Version

SynView Explorer

User Set: Speichern/als Default setzen funktioniert nicht, wenn der User "zu schnell" ist

Issue

IAM-220

SynView-1.03.014.1026

3.10

SynView Explorer

AcquisitionFrameRateTimer Modus: AcquisitionFrameRate kann nicht erhöht werden nach Erhöhung und erneuter Erniedrigung ExposureTime

Issue

IAM-219

SynView-1.03.014.1026

3.10

SynView Explorer

AcquisitionFrameRateTimer Modus: Acquisition bleibt stehen bei Exposure Auto =Continuous/Once

Issue

IAM-218

SynView-1.03.014.1026

3.10

SynView Explorer

AcquisitionFrameRateTimer Modus: Acquisition startet nicht nach Erhöhung Exposure Time

Issue

IAM-217

SynView-1.03.014.1026

3.10

SynView Explorer

IMX265C, IMX264C: keine Frameerzeugung mit BGR 8

Issue

IAM-214

SynView-1.03.014.1026

3.10

SynView Explorer

Color Transformation: schaltet sich aus wenn Start Acquisition

Issue

IAM-210

SynView-1.03.014.1026

3.10

SynView Explorer

BGR 8 Format: Verpixelungen im LiveFrame bei Reduzierung Gamma,Contrast bei bestimmter Helligkeit

Issue

IAM-209

SynView-1.03.014.1026

3.10

SynView Explorer

BalanceRatio(Selector) not shown in as available in Bayer mode

Issue

IAM-207

SynView-1.03.014.1026

3.10

SynView Explorer

IA2312C: Liste der angebotenen Pixelformate nicht korrekt

Issue

IAM-206

SynView-1.03.014.1026

3.10

SynView Explorer

Trigger Modus: Acquisition bleibt stehen bei Triggerrate mit zu hoher Exposure Time

Issue IAM-154

SynView-1.03.014.1026

3.10

SynView Explorer

Acquisition Frame Rate Control: Exposure Time kontrolliert die AcquFrameRate

Issue IAM-149

SynView-1.03.014.1026

3.10

SynView Explorer

Color Transformation: Defaultwert für Color Transformation Value Selector=Offset 2 anstatt Gain 00

Issue IAM-148

SynView-1.03.014.1026

3.10

SynView Explorer

Minwert von Feld "Exposure Auto Max Time" ist kleiner als minimale Exposure Time

Issue IAM-147

SynView-1.03.014.1026

3.10

SynView Explorer

Mono 8 heller als Mono10/12

Issue IAM-142

SynView-1.03.014.1026

3.10

SynView Explorer

Trigger Modus: Acquisition bleibt stehen bei Triggerrate mit zu hoher Exposure Time

Issue IAM-123

SynView-1.03.014.1026

3.10

SynView Explorer

Acquisition Frame Rate: write failed Meldung in bestimmter Situation

Issue IAM-122

SynView-1.03.014.1026

3.10

SynView Explorer

User Set Default "none": Daten werden überschrieben

Issue IAM-121

SynView-1.03.014.1026

3.10

SynView Explorer

Digital I/O Control, Line Source "Selected Trigger" liefert keinen Output

Issue IAM-114

SynView-1.03.014.1026

3.10

SynView Explorer

Strobe Source "Static High": verhält sich wie Static Low

Issue IAM-112

SynView-1.03.014.1026

3.10

SynView Explorer

ColorTransformation: wenn ausgeschalten kommt es trotzdem zur Farbänderung

Issue IAM-165

SynView-1.03.014.1026

3.10

SynView Explorer

IA1503, Sensor Strobe: kein Output bei bestimmter Exposure Time kombiniert mit Width, Height

Issue IAM-189

SynView-1.03.014.1026

3.10

Older Release

 Release 01/2022 - 3.01 (2021.1)

Release 01/2022 - 3.01 (2021.1)

Topic

Description

comment

Author

SynView Version

Petalinux Version

FPGA Version

Device Sensor Version

SynView Explorer

Brightness Control - BCRM Mode / Exposure Auto

Color Management -BCRM Mode / White Balance Auto
→ If "Once" is chosen, "Once" stays active. "OFF" is not active.

IAM-85

AKr

SynView-1.03.010.1090

2.02

34658

iAMGigEServeriAMGigEServer

Events can´t be send via GigE Server

.

MW

SynView-1.03.010.1090

2.02

SynView Explorer

Image Format:

Pixel format:
YUV-frame is brighter than BGR8-frame

Issue IAM-76

DP

SynView-1.03.010.1090

2.02

SynView Explorer

First frame occures to "flash"

GD

SynView-1.03.010.1090

2.02

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView IP Config Tool

sv.ipconf.x64

Re-enable the GigE Vision Server autostart sometimes fails after power cycle.

GD

SynView-1.03.010.1090

2.02

 Release 06/2021 - 2.02 (2020.1).

Release 06/2021 - 2.02 (2020.1)

Topic

Description

comment

Author

SynView Version

Petalinux Version

FPGA Version

Device Sensor Version

SynView Explorer

Brightness Control - BCRM Mode / Exposure Auto

Color Management -BCRM Mode / White Balance Auto
→ If "Once" is chosen, "Once" stays active. "OFF" is not active.

IAM-85

AKr

SynView-1.03.010.1090


2.02



34658

iAMGigEServer

Events can´t be send via GigE Server

.

MW

SynView-1.03.010.1090

2.02



SynView Explorer

Image Format:

Pixel format:
YUV-frame is brighter than BGR8-frame

Issue IAM-76

DP

SynView-1.03.010.1090

2.02

SynView Explorer

First frame occures to "flash"

GD

SynView-1.03.010.1090

2.02

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView IP Config Tool

sv.ipconf.x64

Re-enable the GigE Vision Server autostart sometimes fails after power cycle.

GD

SynView-1.03.010.1090

2.02

 Release 10/2020 - 1.04

Release 10/2020 - 1.04

Topic

Description

comment

Author

SynView Version

Petalinux Version

FPGA Version

BCRM Version

SynView Explorer

Brightness Control - BCRM Mode / Exposure Auto

Color Management -BCRM Mode / White Balance Auto
→ If "Once" is chosen, "Once" stays active. "OFF" is not active.

Issue IAM-85

AKr

1.03.010.1060




SynView Explorer

Events can´t be send via GigE Server

.

MW

1.03.010.1061-8.10.2020




SynView Explorer

Timer/Puls generator can´t be enabled or disabled with Acquisition Start/Stop

.

MW

1.03.010.1061-8.10.2020




SynView Explorer

TriggerMode: Trigger Invert operates sensor in free-run mode

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

StrobeMode: Strobe assigned to wrong edge

.

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

StrobeMode:  Strobe source: Static low remains high

.

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

TriggerMode:  Software trigger
→ Strobe not available

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

I/O
→ Line5 OUT:  On -> Low, OFF → High

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

I/O:
→ Line4 OUT: No function

.

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

Image Format:

Pixel format:
Format Bayer GR 10 Packed cannot be displayed
Format Bayer GR 10 Packed cannot be displayed

Issue SYN-16

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

Image Format:

Pixel format:
BayerRG8-frame is brighter than BGR8-frame

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

Image Format:

Pixel format:
YUV-frame is brighter than BGR8-frame

Issue IAM-76

DP

SynView Explorer

First frame occures to "flash"

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

SynView Explorer

Soft image due to missing basic sensor configuration

(gamma, black level)

GD

1.03.010.1061-19.10.2020

1.04

0x56010102, 0x5f7db0a3

bcrm: 0000797500000300

Hardware

Topic

Description

Affects

Author

Power supply

Power over Ethernet is not supported even though the camera will be detected as a PoE device by a PoE injector!

If the camera serial number has an X or Z in the 9th digit (e.g. 14A2GEBAX2042013)

BH

Input and Output Interface

OUT_GP1+ is out of order and can be used in current revison. Output stays GND. This means in

SynView Explorer I/O: → Line4 OUT: No function (always one!)

If the camera serial number has an X or Y in the 9th digit (e.g. 14A2GEBAX2042013)

BH

  • No labels