Excerpt | |
---|---|
|
Software
Release 01/2022 - 3.10 (2021.1)
Topic | Description | comment | SynView Version | Petalinux Version |
---|---|---|---|---|
User Set: save does not work, when next load is done to fast. | Issue IAM-220 | SynView-1.03.014.1026 | 3.10 | |
AcquisitionFrameRateTimer mode: AcquisitionFrameRate cannot be increased after increase/decrease exposure time. | Issue IAM-219 | SynView-1.03.014.1026 | 3.10 | |
AcquisitionFrameRateTimer mode: acquisition stops if Exposure Auto = Continuous/Once. | Issue IAM-218 | SynView-1.03.014.1026 | 3.10 | |
AcquisitionFrameRateTimer mode: Acquisition does not start after increasing exposure time. | Issue IAM-217 | SynView-1.03.014.1026 | 3.10 | |
IMX265C, IMX264C: no frame output with BGR 8 format. | Issue IAM-214 | SynView-1.03.014.1026 | 3.10 | |
Color Transformation: switches to OFF when aqusition is started. | Issue IAM-210 | SynView-1.03.014.1026 | 3.10 | |
BGR 8 format: wrong pixels can occur when Gamma,Contrast is reduced by certain brightness. | Issue IAM-209 | SynView-1.03.014.1026 | 3.10 | |
BalanceRatio(Selector) not shown as available in bayer mode. | Issue IAM-207 | SynView-1.03.014.1026 | 3.10 | |
IA2312C: list of pixelformats is not correct. | Issue IAM-206 | SynView-1.03.014.1026 | 3.10 | |
Trigger Modus : Acquisition bleibt stehen bei Triggerrate mit zu hoher Exposure Timewith trigger source timer: Acquisition stops when exposure time is to high. | Issue IAM-154 | SynView-1.03.014.1026 | 3.10 | |
Acquisition Frame Rate Control: Exposure Time kontrolliert die AcquFrameRateexposure time controls the AcquFrameRate. | Issue IAM-149 | SynView-1.03.014.1026 | 3.10 | |
Color Transformation: Defaultwert für default-value for Color Transformation Value Selector=Offset 2 anstatt instead of Gain 00. | Issue IAM-148 | SynView-1.03.014.1026 | 3.10 | |
Minwert von Feld minimal value of field "Exposure Auto Max Time" ist kleiner als minimale Exposure Timeis smaler than minimal exposure time. | Issue IAM-147 | SynView-1.03.014.1026 | 3.10 | |
Mono 8 heller als is brighter as Mono10/12. | Issue IAM-142 | SynView-1.03.014.1026 | 3.10 | |
Trigger Modus: Acquisition bleibt stehen bei Triggerrate mit zu hoher Exposure Timeacquisition stops with triggerrate in relation with too high exposure time. | Issue IAM-123 | SynView-1.03.014.1026 | 3.10 | |
Acquisition Frame Rate: write failed Meldung in bestimmter Situationmessage can occur . | Issue IAM-122 | SynView-1.03.014.1026 | 3.10 | |
User Set Default "none": Daten werden überschriebendata will be overwritten. | Issue IAM-121 | SynView-1.03.014.1026 | 3.10 | |
Digital I/O Control, Line Source "Selected Trigger" liefert keinen Outputdelivers no frame output. | Issue IAM-114 | SynView-1.03.014.1026 | 3.10 | |
Strobe Source "Static High": verhält sich wie behaves like "Static Low". | Issue IAM-112 | SynView-1.03.014.1026 | 3.10 | |
ColorTransformation: wenn ausgeschalten kommt es trotzdem zur Farbänderungif switched to off, it still affects the colors of the frame. | Issue IAM-165 | SynView-1.03.014.1026 | 3.10 | |
IA1503, Sensor Strobe: kein Output bei bestimmter no Frame-output with certain Exposure Time kombiniert mit combined with Width, Height. | Issue IAM-189 | SynView-1.03.014.1026 | 3.10 |
Older Release
Expand | ||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||
Release 01/2022 - 3.01 (2021.1)
|
Expand | ||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||
Release 06/2021 - 2.02 (2020.1)
|
Expand | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Release 10/2020 - 1.04
|
Hardware
Topic | Description | Affects | Author |
---|---|---|---|
Power over Ethernet is not supported even though the camera will be detected as a PoE device by a PoE injector! | If the camera serial number has an X or Z in the 9th digit (e.g. 14A2GEBAX2042013) | BH | |
OUT_GP1+ is out of order and can be used in current revison. Output stays GND. This means in SynView Explorer I/O: → Line4 OUT: No function (always one!) | If the camera serial number has an X or Y in the 9th digit (e.g. 14A2GEBAX2042013) | BH |
...