Start Synview Explorer first time

Since the iAMGigE-server is preinstalled to cameras autostart. You can use GigEVision Software to recive camera images.

For iam you need the latest version of Synview Explorer. Please update your Host System. On can find a download link at the end of section Synview .

 1. Connect the camera to be tested - Start Synview Explorer on your Host System. iam camera should apear in the list of found cameras - if not check previus section. Select it in the and press the Connect camera button

 2. Configure the camera features as desired. Pay attention especially to features in Image Format Control and Acquisition Control categories.

 3. When prepared, click the Start acquisition button – the camera should start acquiring. If not, verify again, if the camera was not set to triggered mode, while no trigger was attached.

 4. While the acquisition is active, you can still adjust the runtime parameters, such as exposure time or gain – but basic acquisition parameters, such as pixel format or trigger mode become locked when the acquisition starts.

 5. When finished, click the Stop acquisition button and exit.
SynviewExplorer_aquision_stop

If you want to learn more about Synview Explorer skip next section and read through section “Getting started with Synview Explorer - and become ready to try Option 2.” first.