Factory IP and System Settings
Out-of-the box the iam system comes with the factory settings below.
IP Address | 192.168.1.10 |
root user name | root |
root user passwort | root |
The iAMGigEServer is run by autostart to allow remote IP configuration with SynView IP Config Tool even if you Network Controller Configuration is not set properly.
During production the latest version of the SynView and iAMGigEServer is installed to camera. Only in special cases it is necessary to update the camera. See section iam update tool for detailed information.
Requirements
It is mandatory to have iAMGigEServer runing on iam system to use the SynView IP Config Tool.
Installation of the latest version of SynView to host system. See Section SynView Explorer for download link.
During production the latest version of the SynView Explorer and iAMGigEServer is installed to camera. Only in special cases it is necessary to update the camera. See section iam update tool for detailed information.
After instalation of latest Synview Prerelease the SynView IP Config Tool sv.ipconf.x64 can be found on your host-pc under the location:
C:\Program Files\SynView\bin\sv.ipconf.x64.exe
Change IP Adress
The IP Adress of iam camera is a an important settings affecting the major interface and will therfore define the accessibility of the system.
This important feature can be set by the SynView IP Config Tool even if you Network Controller Configuration is not set properly.
iam operates with static ip settings du to the GenICam - Standard conformity
The ip adress can be changed temporary and persistent. For changing the persistent ip adress it is mandatory to have the proper access to the system, eg. by change the ip adress temporary first.
Temporary Change of IP Settings
With SynView IP Config Tool (sv.ipconf.x64.exe) tool
Open sv.ipconf.x64.exe tool.
Now you should see the iam camera under "device model" even if the camera is not in the correct subnet.
Enter below “Current IP settings” or “Restart IP chonfiguration” for obtaining the persistent settings.
Press button "Force IP adress".
Persistent Change of IP Settings
With SynView IP Config Tool (sv.ipconf.x64.exe) tool
Open sv.ipconf.x64.exe tool.
Now you should see the iam camera under "device model".
Press button "Connect and configure".
Enter below checkbox “Persistent IP adress”
Press button "Use current IP adress".
Press button "Apply and disconnect".