The iAMGigEServer is a small software application, which is preinstalled to the camera autostart script. It provides a comfortable way to set up the vision application on a host system. Obtaining a high-performance live stream from the camera, analyzing image quality or testing new camera settings can be done quickly.
Note |
---|
While sv. iAMGigEServer is running, it will block the camera access for other applications e.g. like SynView Explorer#Explorer running directly on the camera. |
Note |
---|
iAMGigEServer is pre-installed and out of the box by default. |
After setting up the system it is necessary to disable the iAMGigEServer autostart for accessing the camera hardware from the iam camera application.
This can be done with sv.ipconf.x64.exe SynView IP Config Tool.
Drawio | ||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
...
To use the iAMGigEServer it is mandatory to configure the network controller for high data throughput. See Configure your Network Controller for more details.
Installation of the latest version of SynView to host system. See Section Download latest SynView ExplorerPackage for download link.
During production the latest version of the SynView Explorer and iAMGigEServer is installed to camera. Only in special cases it is necessary to update the camera. See section SynView Update Tool for detailed information.
The behaviour of the iAMGigEServer can be controlled by the sv.ipconf.x64 tool. sv.ipconf.x64 SynView IP Config Tool. SynView IP Config Tool can be found on your host PC under "C:\Program Files\SynView\bin\sv.ipconf.x64.exe"
...
Tip |
---|
iAMGigEServer is pre-installed and starts with an autostart script. Therefore it is usually not necessary to start iAMGigEServer manually. |
If the sv.ipconf.x64 tool does not find a connected camera, iAMGigEServer is stopped or disabled.
To get access to iam via sv.ipconf.x64.exe-tool SynView IP Config Tool,
an openSSH connection to the camera has to be established and iAMGigEServer has to be started manually.
ssh root@192.168.1.10
root@iam_mipi:~# /opt/synview/bin/sv.iAMGigEServer
From Comand Line (eg. SSH)
sv.iAMGigEServer
...
Stop iAMGigEServer
From Comand Line (eg. SSH)
create file: "/opt/synview/bin/sv.iAMGigEServer.stop":
touch /opt/synview/bin/sv.iAMGigEServer.stop
With SynView IP Config Tool#Tool (sv.ipconf.x64.exe) tool
Open sv.ipconf.x64.exe tool SynView IP Config Tool .
Now you should see the iam camera under "device model".
Press button "Connect and configure".
Press button "Stop GigEServer".
iam immediately disappears from sv.ipconf-tool.
...
With SynView Explorer on the host PC
Open sv.explorer.x64.exe.
Now you should see iam under “found cameras“.
Open the iam.
Press “Show guru level“.
Open “Smart Application Features“.
Press “Smart Application Exit Event“ command.
iam disappears from sv.explorer.x64.exe. SynView Explorer.
...
Disabling the start of iAMGigEServer after booting
Open SynView IP Config Tool# (sv.ipconf.x64.exe) toolTool .
Now you should see the camera under "device model".
Press button "Connect and configure".
Set "Boot switch" checkbox to checked.
Set Boot switch mode to "None".
Press button "Apply and disconnect".
...
Info |
---|
You need an openSSH connection to the camera to start iAMGigEServer. ssh root@192.168.1.10 Following this commands, the camera shows up again in the SynView IP Config Tool# sv.ipconf.x64.exe tool.Tool . |
Open SynView IP Config Tool# sv.ipconfx64.exe toolTool .
Now you should see the camera under "device model".
Press button "Connect and configure".
Set "Boot switch" checkbox to checked.
Set Boot switch mode to "Autostart GigEServer".
Press button "Apply and disconnect".
...