Camera
iam is a smart vision system which comprises one of the following camera models:
camera model image sensor name resolution [px] max. fps [RAW8] IA2009 M/C IMX287 728 x 544 292 IA2107 M/C IMX273 1456 x 1088 154 IA2305 M/C IMX252 2048 x 1536 118 IA2312 M/C IMX265 2048 x 1536 56 IA2504 M/C IMX250 2448 x 2048 89 IA2511 M/C IMX264 2448 x 2048 36 IA1503 M/C AR0521 2592 x 1944 67 AR0522 2592 x 1944 67 IMX226 4072 x 3046 41 See Camera Model Overview for detailed information. The camera model is labeled on the bottom side of camera housing.
Xilinx Zynq UltraScale+ EG 02, 2 GByte DDR4
Quad-core ARM Cortex-A53 MPCore 1.2GHz (application processing unit)
Dual-core ARM Cortex-R5 MPCore up to 600MHz (real-time processing unit)
Mali™-400 MP2 GPU
Power over Ethernet 802.3at Type 1 (check Known Issues - Prototype Cameras if you have early acces to a protoyp camera)
Factory IP and System Settings
Out-of-the box the iam system comes with the factory settings below.
IP Address | 192.168.1.10 |
root user name | root |
root user passwort | root |
The iAMGigEServer is run by autostart to allow remote IP configuration with SynView IP Config Tool even if you Network Controller Configuration is not set properly.
During production the latest version of the SynView and iAMGigEServer is installed to camera. Only in special cases it is necessary to update the camera. See section iam update tool for detailed information.
Development Tools / Software
Software on Camera
SynView-1.03.010.1090 see section SynView
various open Source Third Party Libraries is installed on the system see section https://net-iam.atlassian.net/wiki/pages/resumedraft.action?draftId=848658453 for details.
widely-used comerial vision libraries such as HALCON, MIL (Matrox Imaging Library)# and /wiki/spaces/iam/pages/844627987 can be pre-installed optionally. Please contact our Sales.
older releases
Software Examples
See chapter Applications# for details.