Starting the Synview Explorer for the first time
1. Connect the camera to be tested: start Synview Explorer on your host system. iam should apear in the list of found cameras. If not, check the previous section ("Configure your Network Controller"). Select it in the list of found cameras and press the "Connect camera" button.
2. Configure the camera features as desired. Pay special attention to features in the categories "Image Format Control" and "Acquisition Control".
3. When prepared, click the "Start acquisition" button to start the camera acquiring imaages. If not, verify again, if the camera was set to triggered mode, and if a trigger was attached.
4. While acquisition is active, you can still adjust the runtime parameters, such as exposure time or gain. Basic acquisition parameters, such as pixel format or trigger mode get locked when acquisition starts.
5. When finished, click "Stop acquisition" button and exit.