You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 3
Next »
Start Synview Explorer first time
1. Connect the camera to be tested - Start Synview Explorer on your Host System. iam camera should apear in the list of found cameras - if not check previus section. Select it in the and press the Connect camera button
2. Configure the camera features as desired. Pay attention especially to features in Image Format Control and Acquisition Control categories.
3. When prepared, click the Start acquisition button – the camera should start acquiring. If not, verify again, if the camera was not set to triggered mode, while no trigger was attached.
4. While the acquisition is active, you can still adjust the runtime parameters, such as exposure time or gain – but basic acquisition parameters, such as pixel format or trigger mode become locked when the acquisition starts.
5. When finished, click the Stop acquisition button and exit.