Connector and cable description - Case Code A
...
| Connectors
|
...
Ethernet connector
| iam is equipped with a standard Ethernet connector, 8P8C modular plug, often also referred to RJ-45. |
I/O Connector
14-pin DLP (dual-inline-pin) connector for digital iI/o O and power input. An adapter cable is available (see Section “Accessories”).
Pinnout
Pin #
Schematic Name
note
1
AUX_POWER
auxiliary power supply voltage
2
GND_P
auxiliary power supply Ground
3
IN_TRIGGER+
Optocoupler Input TRIGGER Anode
4
IN_TRIGGER-
Optocoupler Input TRIGGER Cathode
5
IN_ENC1+
Optocoupler Input 1 Anode
6
IN_ENC2+
Optocoupler Input 2 Anode
7
IN_ENC3+
Optocoupler Output 3 Anode
8
IN_ENC_GND
Optocoupler 1-3 Input Cathode
9
OUT_GP1+
Optocoupler Output 1 Collector
10
OUT_GP2+
Optocoupler Output 2 Collector
11
OUT_GP_GND
Optocoupler Output 1-2 Emitter
12
OUT_STROBE+
Optocoupler Output STROBE Collector
13
OUT_STROBE-
Optocoupler Output STROBE Emitter
14
SGND_IO
Connector and cable description - Case Code A
...
| Connectors
|
Ethernet connector
iamIP67 is equipped with one M12-X and one M16-X Ethernet connector. | ||
M12-X - cable connector (matching type) | standard Gigabit Ethernet Connector diverse Vendors, e. g. M12-X Male cable connector, Contacts: 8, 5.5-9.0 mm, shieldable, cutting clamp, IP67, Binder 99 3787 810 08 | |
M16-X - cable connector (matching type) | M16-X Male cable connector, Contacts: 8, 5.5-9.0 mm, shieldable, cutting clamp, IP67, Binder 99 4171 00 08 |
I/O Connector
17-pin male M12 connector for digital i/o (optocoupler and TTL inputs/outputs) and power input.
An adapter cable is available (see Section “Cable Assembly”), with D-sub 25-pin female interface connector. | |
Cable connector: PHÖNIX M12-17P No. 1559644 | Cable connector: diverse Vendors, e. g. |
Pinout
...
Excel | ||
---|---|---|
|
...
Cable Assembly
Case Code A:
Info |
---|
This cable is fully shielded. |
|
Case Code C:
|