Windows Host System
Introduction
Linux and Mac supports openSSH with X-Server Forwarding nativ. In case of windows some special tool are required. In this section a brew introduction is given.
Once you have configure your windows ethernet adapter you can test the settings with ping command:
Code Block |
---|
ping 192.168.1.10 |
System Requirements:
In order to view a live stream , for example with synview
, you can use the tools listed below.
Install putty on your windows machine
putty will do the ssh-connection to the iam-camera.Install Xming
Xming will do the graphical interface on windowsInstall WinSCP
WinSCP is a program to transfer files from/to the iam camera.
The tools above for Win64 can be downloaded from below.
Attachments | ||||
---|---|---|---|---|
|
WinSCP - Filetransfer to camera:
Info |
---|
WinSCP is a program to transfer files from/to the iam camera: https://winscp.net/eng/docs/lang:de |
The configuration of WinSCP should look like follows:
The iam camera asks for a password.
Tip |
---|
The password is |
PuTTY and Xming - Open applications with graphical user interfaces:
Xming
For using X-Server forwarding on need to start the Xming
Server first. You should have a link in your windows start menue.
Tip |
---|
After launching on should see the Xming Symbol in your task bar. |
If you start Xming the first time, you may get asked by the windows firewall to create an exception for Xming.
Configuration of putty:
Insert the iam ip address
192.168.1.10
in "Session→Host name"
Configure "Connection->SSH→X11" as follows:
Info |
---|
A link to a configuration help page: http://www.geo.mtu.edu/geoschem/docs/putty_install.html |
If you connect to iam the first time you may get asket the following warning. You need to confirm with "yes".
After opening that connection, login as
Tip |
---|
User: Password: |
Start synview:
Type into console:
|
Info |
---|
It is an common sources of error to operate an monochrom sensor in the colour space. If you reviced an monochrome sensor you should change the |
Please be aware, that you get only a low frame refresh rate with this type of connection.
A better refresh rate will be achieved with the "GigEvision server of synview" in the future.
For more information see section Synview above.
Start halcon viewer from then test_halcon_samples:
Info |
---|
Halcon can be preinstalled to your camera. See Halcon fore more information. |
Type into console:
|
Info |
---|
"Image Format Control → Pixel Format" to Mono8 is set inside "test_halcon_live_view" |