...
Unpack the camera, connect all the necessary peripheral. If needed, check the interface connectors description in Section, “Connector and cable description” .
Power up the camera using proper 24V power supply.
Assuming that the desired operating system is already pre-installed on the camera, no additional steps are needed and the camera is ready for SynView installation and test. Otherwise, install the operating system, following instructions of the operating system supplier. Install the necessarydevice drivers available from our download area.
...
The Trigger Source enumeration allows to select where should the camera “listen for triggers. You can select either Software or one of the camera's I/O lines. The assignment of the I/O lines to the connector pins is described in Section, “Connector and cable description” .
Software triggering
The software triggers can be issued during active acquisition in triggered mode, regardless whether the trigger source is set to Software or a physical I/O line. To apply the software trigger, select the Generate Software Trigger feature and click the button in the tool bar.
...
The strobe can be configured using features in the Digital I/O Control category, after switching the feature visibility level to “expert”. Select the desired output line, where the strobe pulses should be applied through Line Selector (the I/O line mapping to interface connector pins is described in Section, “Connector and cable description” ). Switch the strobe on for the selected line by setting Line Source to Exposure Active. The camera will issue a strobe pulse aligned with the exposure for every acquired frame. The strobe output is available only in triggered mode. In case the camera has an integrated Strobe Ring, its Strobe can be controlled through the Strobe Control category. Select which Clusters to use with Strobe Enable. Strobe Duration sets the length of the Strobe Pulse.
...